Notes:
1. Circuit ground is internally isolated from chassis ground.
2. TFAULTis an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on the host board if intended
for use. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high output indicates a transmitter fault caused by either the TX bias
current or the TX output power exceeding the preset alarm thresholds. A low output indicates normal operation. In the low state, the
output is pulled to 2.0V or open, enabled on TDIS<0.8V.
4. Should be pulled up with 4.7k – 10 kohms on host board to a voltage between 2.0V and 3.6V.
MOD_DEF(0) pulls line low to indicate module is plugged in.
5. LOS is open collector output. Should be pulled up with 4.7k – 10 kohms on host board to a voltage between 2.0V and 3.6V. Logic 0
indicates normal operation; logic 1 indicates loss of signal.


Figure 2 Example SFP Host Board Schematic

Figure 3 Recommended Host Board Supply Filtering Network
Small Form-factor Pluggable (SFP) Transceiver MultiSource Agreement (MSA)

Figure 4 SFP Host Board Mechanical Layout

Figure 5 SFP Host Board Mechanical Layout (Cont.)

Figure 6 Recommended Bezel Design